On Tue, 26 May 1998, Mark Dabrowski wrote:
> Ok, here's what I've done:
> 
> We have ordered 3 new Adaptec 2940 U2W controllers (UltraWide 2) which go
> 80MB/s, but unfortunately couldn't find anywhere 4GB Ultra Wide 2 drives
> and also BSD 3.1 does not recognize (support) 2940U2W at all ...
> 
> So we ended up installing 2 more 2940 UW's and adding 2 x 4GB drives.
> 
> The disk configuration of Squid box is 3 AHA 2940 UW controllers and 1 X
> 9GB Drive and 2 X 4.5GB drives. I have defined 3 equal partitions in
> cache_dir, each on each disk.
> 
> Since we just finished installation, i didn't have a chance to make any
> tests, but when the system is almost idle and only 5-10 clients use squid
> there is something weird happening... Every 15-20 seconds I would notice
> number of disk operations/sec jump to about 100 on each disk (which causes
> cpu idle to go down to 100%) and then resumes normally.
> 
> Is squid doing some disk operations every 15-20 seconds? If yes, under
> normal conditions I would not  think it can halt the system.... but it
> does... Any ideas?
Did you stripe the drives with RAID0?  I personally recommend a 4*2GB
configuration, RAID0 striped.
Brian
> 
>  procs     memory      page                     disks          faults      cpu
>  r  b w    avm    fre  flt  re  pi  po  fr  sr  s0  s1  s2   in   sy  cs us
> sy  id
>  0  2 0 129396 199540    5   1   1   1   0   1   3   3   3  205  536  41  2
>  2  96
>  1  2 0 129396 199540    5   1   1   1   0   1   0   3   4  228  795  63  0
>  6  94
>  1  2 0 129396 199540    5   1   1   1   0   1   6   7   3  289 1242  78  4
>  6  90
>  0  2 0 129396 199548    6   1   1   1   0   1   3   4   4  299 1383  89  1
> 11  88
>  1  2 0 129396 199556    5   1   1   1   0   1   8   4   6  298 1255  83  4
> 10  86
>  0  2 0 129936 199556    5   1   1   1   0   1   0   6   0  226  681  57  3
>  3  94
>  0  2 0 129936 199560    5   1   1   1   0   1   3   3   5  268  932  63  3
>  0  97
>  0  2 0 129936 199568    5   1   1   1   0   1   6   5   6  254 1010  69  1
>  8  91
>  0  3 0 130388 199568    5   1   1   1   0   1  63 108 104  481  392  33  2
>  2  100
>  0  2 0 130388 199580    5   1   1   1   0   1  81  31  15  353  788  28  3
>  5  96
>  0  2 0 130388 199580    5   1   1   1   0   1   3   3   6  210  585  48  4
>  2  94
>  0  2 0 130388 199580    5   1   1   1   0   1   0   0   0  198  384  33  0
>  1  99
>  0  2 0 130388 199580    5   1   1   1   0   1   0   1   0  188  564  46  1
>  2  97
>  0  2 0 130388 199580    5   1   1   1   0   1   3   5   0  239  734  60  3
>  2  95
>  0  2 0 130388 199572    9   1   1   1   0   1   1   0   6  202  723  51  2
>  3  95
>  0  2 0 130388 199564    7   1   1   1   0   1   3   3   3  199  420  46  0
>  3  97
>  0  2 0 130388 199564    5   1   1   1   0   1   4   3   0  203  573  56  3
>  5  92
>  0  2 0 130388 199564    5   1   1   1   0   1   0   0   3  200  606  56  1
>  2  97
>  0  2 0 130388 199564    5   1   1   1   0   1   3   0   0  183  372  36  2
>  2  96
> 
> 
> Mark Dabrowski
> 
> 
> At 12:04 5/27/98 +1200, you wrote:
> >+ Are you running ultra drives? is ultra enabled? How many Commands are you
> >+ sending to the controller simultaneously?  You can genereally tweak the
> >+ 2940 quite a bit, enable tag queueing, paging, ultra, etc.
> >
> >Could be worth it but for a single disk 100 IOPS is about what you'd expect.
> >
> >Go with the earlier advice and get a couple of disks and stripe across them.
> >The bottleneck shouldn't be on the controller (unless it is quite broken), so
> >you should be able to put the disks on the same controller and get really
> good
> >performance increase.
> 
> 
> +------------------------------------------<<<
> +  Mark Dabrowski @ Canada On-Line  @ Toronto, Ontario
> +  Tel: (905) 624-8566 ext.5067, Fax: (905) 624-5397, mark@ica.net
> +  For technical inquires please email support@ica.net or call our
> +  Technical Support Department at (905) 624-1953.
> +------------------------------------------------------------------>>>
> 
/-------------------------- signal@shreve.net -----------------------------\
| Brian Feeny                | USR TC Hubs | ShreveNet Inc. (318)222-2638  |
| Network Administrator      | Perl, Linux | Web hosting, online stores,   |
| ShreveNet Inc.             |  USR Pilot  | Dial-Up 14.4-56k, ISDN & LANs |
| 89 CRX DX w/MPFI, lots of  |-=*:Quake:*=-| http://www.shreve.net/        |
| mods/Homepage coming soon  |LordSignal/SN| Quake server: 208.206.76.47   |
\-------------------------- 318-222-2638 x109 -----------------------------/
Received on Wed May 27 1998 - 06:51:40 MDT
This archive was generated by hypermail pre-2.1.9 : Tue Dec 09 2003 - 16:40:21 MST